        "key": "WE42ISGQ",
        "version": 2,
        "library": {
            "type": "group",
            "id": 75632,
            "name": "TABS Thermo-Active-Building-Systems = thermoaktive Bauteilsysteme",
            "links": {
                "alternate": {
                    "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme",
                    "type": "text/html"
                }
            }
        },
        "links": {
            "self": {
                "href": "https://api.zotero.org/groups/75632/items/WE42ISGQ",
                "type": "application/json"
            },
            "alternate": {
                "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme/items/WE42ISGQ",
                "type": "text/html"
            }
        },
        "meta": {
            "createdByUser": {
                "id": 932721,
                "username": "anper47",
                "name": "Antonio Peretti",
                "links": {
                    "alternate": {
                        "href": "https://www.zotero.org/anper47",
                        "type": "text/html"
                    }
                }
            },
            "creatorSummary": "PERETTI",
            "parsedDate": "2009",
            "numChildren": 0
        },
        "data": {
            "key": "WE42ISGQ",
            "version": 2,
            "itemType": "thesis",
            "title": "STRATEGIE INNOVATIVE per la RIQUALIFICAZIONE ENERGETICA (TABS e MPPF)",
            "creators": [
                {
                    "creatorType": "author",
                    "firstName": "Antonio",
                    "lastName": "PERETTI"
                }
            ],
            "abstractNote": "Si studiano procedure nuove per la riqualificazione energetica di edifici esistenti, con particolare riferimento al residenziale. \nFissato come caso di studio un comune condominio multipiano del secondo dopoguerra, tema della tesi sono le possibilità di attivare ex post le componenti edilizie più dotate di massa, e cioè i solai e le pareti perimetrali, le modifiche e/o l'interazione con l'impiantistica esistente, la VMC (ventilazione meccanica controllata), le fonti energetiche alternative e la relativa modellazione / simulazione. \nSi confrontano le procedure standard di intervento (cappotto / serramenti / impianti) con varianti innovative (attivazione termica e facciata prefabbricata multifunzione) e si individuano gli interventi e i costi necessari per una ristrutturazione in categoria casaclima B.",
            "thesisType": "",
            "university": "PADOVA",
            "place": "",
            "date": "2009",
            "series": "",
            "seriesNumber": "",
            "numPages": "",
            "DOI": "",
            "ISBN": "",
            "citationKey": "",
            "url": "",
            "accessDate": "",
            "ISSN": "",
            "archive": "",
            "archiveLocation": "",
            "shortTitle": "",
            "language": "italiano",
            "libraryCatalog": "",
            "callNumber": "",
            "rights": "",
            "extra": "",
            "tags": [],
            "collections": [
                "7SA46WUI"
            ],
            "relations": {},
            "dateAdded": "2012-05-09T17:36:06Z",
            "dateModified": "2012-05-09T17:39:05Z"
        }
    },
    {
        "key": "R7UZ5K7J",
        "version": 2,
        "library": {
            "type": "group",
            "id": 75632,
            "name": "TABS Thermo-Active-Building-Systems = thermoaktive Bauteilsysteme",
            "links": {
                "alternate": {
                    "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme",
                    "type": "text/html"
                }
            }
        },
        "links": {
            "self": {
                "href": "https://api.zotero.org/groups/75632/items/R7UZ5K7J",
                "type": "application/json"
            },
            "alternate": {
                "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme/items/R7UZ5K7J",
                "type": "text/html"
            }
        },
        "meta": {
            "createdByUser": {
                "id": 932721,
                "username": "anper47",
                "name": "Antonio Peretti",
                "links": {
                    "alternate": {
                        "href": "https://www.zotero.org/anper47",
                        "type": "text/html"
                    }
                }
            },
            "creatorSummary": "KOLARIK",
            "numChildren": 0
        },
        "data": {
            "key": "R7UZ5K7J",
            "version": 2,
            "itemType": "presentation",
            "title": "THERMAL MASS ACTIVATION - state of the art and perspectives",
            "creators": [
                {
                    "creatorType": "presenter",
                    "firstName": "Jakub",
                    "lastName": "KOLARIK"
                }
            ],
            "abstractNote": "",
            "presentationType": "",
            "date": "",
            "meetingName": "",
            "place": "",
            "series": "",
            "sessionTitle": "",
            "DOI": "",
            "citationKey": "",
            "url": "http://www.annex44.civil.aau.dk/Annex%2044%20Forum/meetings/4th%20Annex%2044%20Forum/17_Jakub_TMA.pdf",
            "accessDate": "",
            "shortTitle": "",
            "language": "",
            "rights": "",
            "extra": "",
            "tags": [],
            "collections": [
                "IACUM5BK"
            ],
            "relations": {},
            "dateAdded": "2012-04-27T09:12:20Z",
            "dateModified": "2012-04-27T09:13:55Z"
        }
    },
    {
        "key": "7UD9F4FI",
        "version": 1,
        "library": {
            "type": "group",
            "id": 75632,
            "name": "TABS Thermo-Active-Building-Systems = thermoaktive Bauteilsysteme",
            "links": {
                "alternate": {
                    "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme",
                    "type": "text/html"
                }
            }
        },
        "links": {
            "self": {
                "href": "https://api.zotero.org/groups/75632/items/7UD9F4FI",
                "type": "application/json"
            },
            "alternate": {
                "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme/items/7UD9F4FI",
                "type": "text/html"
            },
            "up": {
                "href": "https://api.zotero.org/groups/75632/items/PVMR3VWW",
                "type": "application/json"
            }
        },
        "meta": {
            "createdByUser": {
                "id": 932721,
                "username": "anper47",
                "name": "Antonio Peretti",
                "links": {
                    "alternate": {
                        "href": "https://www.zotero.org/anper47",
                        "type": "text/html"
                    }
                }
            }
        },
        "data": {
            "key": "7UD9F4FI",
            "version": 1,
            "parentItem": "PVMR3VWW",
            "itemType": "attachment",
            "linkMode": "linked_url",
            "title": "ScienceDirect Full Text PDF",
            "accessDate": "2012-04-27T09:09:22Z",
            "url": "http://www.sciencedirect.com/science?_ob=ShoppingCartURL&_method=add&_eid=1-s2.0-S0306261910003260&originContentFamily=serial&_origin=article&_acct=C000228598&_version=1&_userid=10&_ts=1335517740&md5=91ee54fc246fa9f186eadb57eed63fab",
            "note": "",
            "contentType": "application/pdf",
            "charset": "",
            "tags": [],
            "relations": {},
            "dateAdded": "2012-04-27T09:09:22Z",
            "dateModified": "2012-04-27T09:09:22Z"
        }
    },
    {
        "key": "PVMR3VWW",
        "version": 1,
        "library": {
            "type": "group",
            "id": 75632,
            "name": "TABS Thermo-Active-Building-Systems = thermoaktive Bauteilsysteme",
            "links": {
                "alternate": {
                    "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme",
                    "type": "text/html"
                }
            }
        },
        "links": {
            "self": {
                "href": "https://api.zotero.org/groups/75632/items/PVMR3VWW",
                "type": "application/json"
            },
            "alternate": {
                "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme/items/PVMR3VWW",
                "type": "text/html"
            }
        },
        "meta": {
            "createdByUser": {
                "id": 932721,
                "username": "anper47",
                "name": "Antonio Peretti",
                "links": {
                    "alternate": {
                        "href": "https://www.zotero.org/anper47",
                        "type": "text/html"
                    }
                }
            },
            "creatorSummary": "Lehmann et al.",
            "parsedDate": "2011",
            "numChildren": 2
        },
        "data": {
            "key": "PVMR3VWW",
            "version": 1,
            "itemType": "journalArticle",
            "title": "Thermally activated building systems (TABS): Energy efficiency as a function of control strategy, hydronic circuit topology and (cold) generation system",
            "creators": [
                {
                    "creatorType": "author",
                    "firstName": "B.",
                    "lastName": "Lehmann"
                },
                {
                    "creatorType": "author",
                    "firstName": "V.",
                    "lastName": "Dorer"
                },
                {
                    "creatorType": "author",
                    "firstName": "M.",
                    "lastName": "Gwerder"
                },
                {
                    "creatorType": "author",
                    "firstName": "F.",
                    "lastName": "Renggli"
                },
                {
                    "creatorType": "author",
                    "firstName": "J.",
                    "lastName": "Tödtli"
                }
            ],
            "abstractNote": "By integrating the building structure as thermal energy storage into the building services concept, thermally activated building systems (TABS) have proven to be economically viable for the heating and cooling of buildings. Having already developed an integrated design method and various control concepts in the past, in the present paper the impact of different aspects of TABS regarding the energetic performance of such systems is analyzed. Based on a simulation case study for a typical Central European office building, the following conclusions can be drawn. The energy efficiency of TABS is significantly influenced by the hydronic circuit topology used. With separate zone return pipes energy savings of approximately 15–25&#xa0;kW&#xa0;h/m2&#xa0;a, or 20–30% of heating as well as cooling demand, can be achieved, compared to common zone return pipes, where energy losses occur due to mixing of return water. A strong impact on energy efficiency can also be observed for the control strategy. Thus, by intermittent operation of the system using pulse width modulation control (PWM), the electricity demand for the water circulation pumps can be reduced by more than 50% compared to continuous operation. Concerning cold generation for TABS, it is shown that free cooling with a wet cooling tower is most efficient, if the cold source is the outside air. Variants with mechanical chillers exhibit 30–50% higher electricity demands for cold generation and distribution, even though their runtimes are much shorter compared to the cooling tower runtimes. In conclusion, the results show that significant energy savings can be achieved using adapted system topologies and applying appropriate control solutions for TABS.",
            "publicationTitle": "Applied Energy",
            "publisher": "",
            "place": "",
            "date": "Gennaio 2011",
            "volume": "88",
            "issue": "1",
            "section": "",
            "partNumber": "",
            "partTitle": "",
            "pages": "180-191",
            "series": "",
            "seriesTitle": "",
            "seriesText": "",
            "journalAbbreviation": "",
            "DOI": "10.1016/j.apenergy.2010.08.010",
            "citationKey": "",
            "url": "http://www.sciencedirect.com/science/article/pii/S0306261910003260",
            "accessDate": "2012-04-27T09:09:22Z",
            "PMID": "",
            "PMCID": "",
            "ISSN": "0306-2619",
            "archive": "",
            "archiveLocation": "",
            "shortTitle": "Thermally activated building systems (TABS)",
            "language": "",
            "libraryCatalog": "ScienceDirect",
            "callNumber": "",
            "rights": "",
            "extra": "",
            "tags": [
                {
                    "tag": "Concrete core conditioning",
                    "type": 1
                },
                {
                    "tag": "Energy efficiency of cold generation",
                    "type": 1
                },
                {
                    "tag": "HVAC control",
                    "type": 1
                },
                {
                    "tag": "Hydronic circuit topology",
                    "type": 1
                },
                {
                    "tag": "Pulse width modulation control, PWM",
                    "type": 1
                },
                {
                    "tag": "Thermally activated building systems, TABS",
                    "type": 1
                }
            ],
            "collections": [
                "7SA46WUI"
            ],
            "relations": {},
            "dateAdded": "2012-04-27T09:09:22Z",
            "dateModified": "2012-04-27T09:09:22Z"
        }
    },
    {
        "key": "E9AIITXW",
        "version": 1,
        "library": {
            "type": "group",
            "id": 75632,
            "name": "TABS Thermo-Active-Building-Systems = thermoaktive Bauteilsysteme",
            "links": {
                "alternate": {
                    "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme",
                    "type": "text/html"
                }
            }
        },
        "links": {
            "self": {
                "href": "https://api.zotero.org/groups/75632/items/E9AIITXW",
                "type": "application/json"
            },
            "alternate": {
                "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme/items/E9AIITXW",
                "type": "text/html"
            },
            "up": {
                "href": "https://api.zotero.org/groups/75632/items/PVMR3VWW",
                "type": "application/json"
            }
        },
        "meta": {
            "createdByUser": {
                "id": 932721,
                "username": "anper47",
                "name": "Antonio Peretti",
                "links": {
                    "alternate": {
                        "href": "https://www.zotero.org/anper47",
                        "type": "text/html"
                    }
                }
            }
        },
        "data": {
            "key": "E9AIITXW",
            "version": 1,
            "parentItem": "PVMR3VWW",
            "itemType": "attachment",
            "linkMode": "linked_url",
            "title": "ScienceDirect Snapshot",
            "accessDate": "2012-04-27T09:09:22Z",
            "url": "http://www.sciencedirect.com/science/article/pii/S0306261910003260",
            "note": "",
            "contentType": "text/html",
            "charset": "",
            "tags": [],
            "relations": {},
            "dateAdded": "2012-04-27T09:09:22Z",
            "dateModified": "2012-04-27T09:09:22Z"
        }
    },
    {
        "key": "2X2IXKKR",
        "version": 1,
        "library": {
            "type": "group",
            "id": 75632,
            "name": "TABS Thermo-Active-Building-Systems = thermoaktive Bauteilsysteme",
            "links": {
                "alternate": {
                    "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme",
                    "type": "text/html"
                }
            }
        },
        "links": {
            "self": {
                "href": "https://api.zotero.org/groups/75632/items/2X2IXKKR",
                "type": "application/json"
            },
            "alternate": {
                "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme/items/2X2IXKKR",
                "type": "text/html"
            },
            "up": {
                "href": "https://api.zotero.org/groups/75632/items/XF95JSJ9",
                "type": "application/json"
            }
        },
        "meta": {
            "createdByUser": {
                "id": 932721,
                "username": "anper47",
                "name": "Antonio Peretti",
                "links": {
                    "alternate": {
                        "href": "https://www.zotero.org/anper47",
                        "type": "text/html"
                    }
                }
            }
        },
        "data": {
            "key": "2X2IXKKR",
            "version": 1,
            "parentItem": "XF95JSJ9",
            "itemType": "attachment",
            "linkMode": "linked_url",
            "title": "ScienceDirect Full Text PDF",
            "accessDate": "2012-04-27T09:08:32Z",
            "url": "http://www.sciencedirect.com/science?_ob=ShoppingCartURL&_method=add&_eid=1-s2.0-S0378778809002217&originContentFamily=serial&_origin=article&_acct=C000228598&_version=1&_userid=10&_ts=1335517681&md5=acfc52d61212186fba2773eec008127c",
            "note": "",
            "contentType": "application/pdf",
            "charset": "",
            "tags": [],
            "relations": {},
            "dateAdded": "2012-04-27T09:08:32Z",
            "dateModified": "2012-04-27T09:08:32Z"
        }
    },
    {
        "key": "BB97ERBQ",
        "version": 1,
        "library": {
            "type": "group",
            "id": 75632,
            "name": "TABS Thermo-Active-Building-Systems = thermoaktive Bauteilsysteme",
            "links": {
                "alternate": {
                    "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme",
                    "type": "text/html"
                }
            }
        },
        "links": {
            "self": {
                "href": "https://api.zotero.org/groups/75632/items/BB97ERBQ",
                "type": "application/json"
            },
            "alternate": {
                "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme/items/BB97ERBQ",
                "type": "text/html"
            },
            "up": {
                "href": "https://api.zotero.org/groups/75632/items/XF95JSJ9",
                "type": "application/json"
            }
        },
        "meta": {
            "createdByUser": {
                "id": 932721,
                "username": "anper47",
                "name": "Antonio Peretti",
                "links": {
                    "alternate": {
                        "href": "https://www.zotero.org/anper47",
                        "type": "text/html"
                    }
                }
            }
        },
        "data": {
            "key": "BB97ERBQ",
            "version": 1,
            "parentItem": "XF95JSJ9",
            "itemType": "attachment",
            "linkMode": "linked_url",
            "title": "ScienceDirect Snapshot",
            "accessDate": "2012-04-27T09:08:32Z",
            "url": "http://www.sciencedirect.com/science/article/pii/S0378778809002217",
            "note": "",
            "contentType": "text/html",
            "charset": "",
            "tags": [],
            "relations": {},
            "dateAdded": "2012-04-27T09:08:32Z",
            "dateModified": "2012-04-27T09:08:32Z"
        }
    },
    {
        "key": "XF95JSJ9",
        "version": 1,
        "library": {
            "type": "group",
            "id": 75632,
            "name": "TABS Thermo-Active-Building-Systems = thermoaktive Bauteilsysteme",
            "links": {
                "alternate": {
                    "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme",
                    "type": "text/html"
                }
            }
        },
        "links": {
            "self": {
                "href": "https://api.zotero.org/groups/75632/items/XF95JSJ9",
                "type": "application/json"
            },
            "alternate": {
                "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme/items/XF95JSJ9",
                "type": "text/html"
            }
        },
        "meta": {
            "createdByUser": {
                "id": 932721,
                "username": "anper47",
                "name": "Antonio Peretti",
                "links": {
                    "alternate": {
                        "href": "https://www.zotero.org/anper47",
                        "type": "text/html"
                    }
                }
            },
            "creatorSummary": "Rijksen et al.",
            "parsedDate": "2010-03",
            "numChildren": 2
        },
        "data": {
            "key": "XF95JSJ9",
            "version": 1,
            "itemType": "journalArticle",
            "title": "Reducing peak requirements for cooling by using thermally activated building systems",
            "creators": [
                {
                    "creatorType": "author",
                    "firstName": "D.O.",
                    "lastName": "Rijksen"
                },
                {
                    "creatorType": "author",
                    "firstName": "C.J.",
                    "lastName": "Wisse"
                },
                {
                    "creatorType": "author",
                    "firstName": "A.W.M.",
                    "lastName": "van Schijndel"
                }
            ],
            "abstractNote": "This paper presents general guidelines for the required cooling capacity of an entire office building using thermally activated building systems (TABS). By activating the thermal mass of the building using pipes embedded in the floor, peak loads can be reduced. On-site measurements were performed to obtain the required cooling power of an entire building as well as individual zones. Beside this, the internal climate conditions of rooms and surface temperatures of the TABS were measured. The measured data were used to analyze the predictive performance of a simulation model. In order to acquire general guidelines for the required cooling capacity of a standard office building, simulations of an entire building were used to determine the impact of variable internal heat gains and different sized windows. The required cooling capacity was compared to the cooling capacity of a system without energy buffering (e.g. chilled ceiling panels). It was found that reductions up to 50% of the cooling capacity for a chiller can be achieved using TABS. The presented results within this paper can be used as design guidelines in the first stage of a design process. The results focus on temperate climates and were derived using Dutch climate conditions.",
            "publicationTitle": "Energy and Buildings",
            "publisher": "",
            "place": "",
            "date": "Marzo 2010",
            "volume": "42",
            "issue": "3",
            "section": "",
            "partNumber": "",
            "partTitle": "",
            "pages": "298-304",
            "series": "",
            "seriesTitle": "",
            "seriesText": "",
            "journalAbbreviation": "",
            "DOI": "10.1016/j.enbuild.2009.09.007",
            "citationKey": "",
            "url": "http://www.sciencedirect.com/science/article/pii/S0378778809002217",
            "accessDate": "2012-04-27T09:08:32Z",
            "PMID": "",
            "PMCID": "",
            "ISSN": "0378-7788",
            "archive": "",
            "archiveLocation": "",
            "shortTitle": "",
            "language": "",
            "libraryCatalog": "ScienceDirect",
            "callNumber": "",
            "rights": "",
            "extra": "",
            "tags": [
                {
                    "tag": "Concrete core cooling (CCC)",
                    "type": 1
                },
                {
                    "tag": "On-site measurements",
                    "type": 1
                },
                {
                    "tag": "Passive building thermal storage",
                    "type": 1
                },
                {
                    "tag": "Peak load reduction",
                    "type": 1
                },
                {
                    "tag": "TRNSYS",
                    "type": 1
                },
                {
                    "tag": "Thermally activated building systems (TABS)",
                    "type": 1
                }
            ],
            "collections": [
                "E7BGXVTJ"
            ],
            "relations": {},
            "dateAdded": "2012-04-27T09:08:32Z",
            "dateModified": "2012-04-27T09:08:32Z"
        }
    },
    {
        "key": "XXXV5A49",
        "version": 3,
        "library": {
            "type": "group",
            "id": 75632,
            "name": "TABS Thermo-Active-Building-Systems = thermoaktive Bauteilsysteme",
            "links": {
                "alternate": {
                    "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme",
                    "type": "text/html"
                }
            }
        },
        "links": {
            "self": {
                "href": "https://api.zotero.org/groups/75632/items/XXXV5A49",
                "type": "application/json"
            },
            "alternate": {
                "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme/items/XXXV5A49",
                "type": "text/html"
            }
        },
        "meta": {
            "createdByUser": {
                "id": 932721,
                "username": "anper47",
                "name": "Antonio Peretti",
                "links": {
                    "alternate": {
                        "href": "https://www.zotero.org/anper47",
                        "type": "text/html"
                    }
                }
            },
            "creatorSummary": "DE CARLI et al.",
            "parsedDate": "2008",
            "numChildren": 0
        },
        "data": {
            "key": "XXXV5A49",
            "version": 3,
            "itemType": "journalArticle",
            "title": "Le prestazioni termiche dei TABS",
            "creators": [
                {
                    "creatorType": "author",
                    "firstName": "Michele",
                    "lastName": "DE CARLI"
                },
                {
                    "creatorType": "author",
                    "firstName": "Markus",
                    "lastName": "KOSCHENZ"
                },
                {
                    "creatorType": "author",
                    "firstName": "Bjarne W.",
                    "lastName": "OLESEN"
                },
                {
                    "creatorType": "author",
                    "firstName": "M.",
                    "lastName": "SCARPA"
                }
            ],
            "abstractNote": "",
            "publicationTitle": "CDA",
            "publisher": "",
            "place": "",
            "date": "2008 settembre",
            "volume": "",
            "issue": "08/09",
            "section": "",
            "partNumber": "",
            "partTitle": "",
            "pages": "24-32",
            "series": "",
            "seriesTitle": "",
            "seriesText": "",
            "journalAbbreviation": "",
            "DOI": "",
            "citationKey": "",
            "url": "",
            "accessDate": "",
            "PMID": "",
            "PMCID": "",
            "ISSN": "",
            "archive": "",
            "archiveLocation": "",
            "shortTitle": "",
            "language": "",
            "libraryCatalog": "",
            "callNumber": "",
            "rights": "",
            "extra": "",
            "tags": [],
            "collections": [
                "IACUM5BK"
            ],
            "relations": {},
            "dateAdded": "2012-04-27T09:04:33Z",
            "dateModified": "2012-04-27T09:07:00Z"
        }
    },
    {
        "key": "3KM796H8",
        "version": 5,
        "library": {
            "type": "group",
            "id": 75632,
            "name": "TABS Thermo-Active-Building-Systems = thermoaktive Bauteilsysteme",
            "links": {
                "alternate": {
                    "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme",
                    "type": "text/html"
                }
            }
        },
        "links": {
            "self": {
                "href": "https://api.zotero.org/groups/75632/items/3KM796H8",
                "type": "application/json"
            },
            "alternate": {
                "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme/items/3KM796H8",
                "type": "text/html"
            }
        },
        "meta": {
            "createdByUser": {
                "id": 932721,
                "username": "anper47",
                "name": "Antonio Peretti",
                "links": {
                    "alternate": {
                        "href": "https://www.zotero.org/anper47",
                        "type": "text/html"
                    }
                }
            },
            "creatorSummary": "DE CARLI et al.",
            "numChildren": 0
        },
        "data": {
            "key": "3KM796H8",
            "version": 5,
            "itemType": "document",
            "title": "AN INNOVATIVE BUILDING BASED ON ACTIVE THERMAL SLAB SYSTEMS",
            "creators": [
                {
                    "creatorType": "author",
                    "firstName": "Michele",
                    "lastName": "DE CARLI"
                },
                {
                    "creatorType": "author",
                    "firstName": "Gerd",
                    "lastName": "HAUSER"
                },
                {
                    "creatorType": "author",
                    "firstName": "Dietrich",
                    "lastName": "SCHMIDT"
                },
                {
                    "creatorType": "author",
                    "firstName": "Roberto",
                    "lastName": "ZECCHIN"
                },
                {
                    "creatorType": "author",
                    "firstName": "Paolo",
                    "lastName": "ZECCHIN"
                }
            ],
            "abstractNote": "The rising demand of primary energy for heating and cooling of residential and commercial buildings implies the design and the realization of energy efficient buildings with a minimal impact on the environment. Many new technologies allowing low supply temperature with low specific emissions and new buildings envelopes (good insulation and solar shadings) seem powerful, but there is the need to optimise control strategies for achieving this aim. The use of active thermal slab systems is a promising solution. Active thermal slab systems are being increasingly used in the centre and in the north of Europe, but some uncertainties still remain, especially as far as the \ncontrol strategy is concerned. Moreover the operation of these buildings has to be investigated more in depth and the resort to field measurements is needed. \nIn this work the use of active thermal slabs systems is described and an innovative pilot project, the building of ZUB (The Centre for Sustainable Building) at the University of Kassel (Germany), is presented. Through a detailed description of its integrated heating and cooling system and its complex measurement system, which allows to collect temperature, comfort and air quality, the efficiency of different solutions and control strategies may be investigated. Up to now data on the operation of the active thermal slab system are being collected and analyzed. Therefore and in order to foresee the best working condition and control strategy, a simulation made by the commercial software TRNSYS 15 has been carried out. Finally, for a seek of completeness, a parametric study for different European climatic conditions is reported (Kassel/Germany, Venice and Palermo/Italy) to look at the possibility to use active thermal slab systems in similar buildings in different countries.",
            "type": "",
            "date": "",
            "publisher": "",
            "place": "",
            "DOI": "",
            "citationKey": "",
            "url": "http://dev.heatinghelp.com/files/articles/717/39.pdf",
            "accessDate": "",
            "archive": "",
            "archiveLocation": "",
            "shortTitle": "",
            "language": "",
            "libraryCatalog": "",
            "callNumber": "",
            "rights": "",
            "extra": "",
            "tags": [],
            "collections": [
                "7SA46WUI"
            ],
            "relations": {},
            "dateAdded": "2012-04-23T10:09:36Z",
            "dateModified": "2012-04-23T21:15:35Z"
        }
    },
    {
        "key": "DXCGM7WP",
        "version": 3,
        "library": {
            "type": "group",
            "id": 75632,
            "name": "TABS Thermo-Active-Building-Systems = thermoaktive Bauteilsysteme",
            "links": {
                "alternate": {
                    "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme",
                    "type": "text/html"
                }
            }
        },
        "links": {
            "self": {
                "href": "https://api.zotero.org/groups/75632/items/DXCGM7WP",
                "type": "application/json"
            },
            "alternate": {
                "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme/items/DXCGM7WP",
                "type": "text/html"
            }
        },
        "meta": {
            "createdByUser": {
                "id": 932721,
                "username": "anper47",
                "name": "Antonio Peretti",
                "links": {
                    "alternate": {
                        "href": "https://www.zotero.org/anper47",
                        "type": "text/html"
                    }
                }
            },
            "numChildren": 0
        },
        "data": {
            "key": "DXCGM7WP",
            "version": 3,
            "itemType": "artwork",
            "title": "photolink-test",
            "creators": [],
            "abstractNote": "",
            "artworkMedium": "",
            "artworkSize": "",
            "date": "",
            "eventPlace": "",
            "DOI": "",
            "citationKey": "",
            "url": "http://www.flickr.com/photos/77339882@N05/6944025194/in/photostream",
            "accessDate": "2012-04-18T11:10:13Z",
            "archive": "",
            "archiveLocation": "",
            "shortTitle": "",
            "language": "",
            "libraryCatalog": "",
            "callNumber": "",
            "rights": "",
            "extra": "",
            "tags": [],
            "collections": [
                "F9NQDG3J"
            ],
            "relations": {},
            "dateAdded": "2012-04-18T11:10:13Z",
            "dateModified": "2012-04-23T17:20:06Z"
        }
    },
    {
        "key": "WUD7X7QQ",
        "version": 4,
        "library": {
            "type": "group",
            "id": 75632,
            "name": "TABS Thermo-Active-Building-Systems = thermoaktive Bauteilsysteme",
            "links": {
                "alternate": {
                    "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme",
                    "type": "text/html"
                }
            }
        },
        "links": {
            "self": {
                "href": "https://api.zotero.org/groups/75632/items/WUD7X7QQ",
                "type": "application/json"
            },
            "alternate": {
                "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme/items/WUD7X7QQ",
                "type": "text/html"
            }
        },
        "meta": {
            "createdByUser": {
                "id": 932721,
                "username": "anper47",
                "name": "Antonio Peretti",
                "links": {
                    "alternate": {
                        "href": "https://www.zotero.org/anper47",
                        "type": "text/html"
                    }
                }
            },
            "creatorSummary": "WARWICK et al.",
            "parsedDate": "2008",
            "numChildren": 0
        },
        "data": {
            "key": "WUD7X7QQ",
            "version": 4,
            "itemType": "conferencePaper",
            "title": "INTEGRATING ACTIVE  THERMAL MASS STRA TEGIES  WITH HVAC SYSTEMS: DYNAMIC  THERMAL MODELLING",
            "creators": [
                {
                    "creatorType": "author",
                    "firstName": "David",
                    "lastName": "WARWICK"
                },
                {
                    "creatorType": "author",
                    "firstName": "A. J.",
                    "lastName": "CRIPPS"
                },
                {
                    "creatorType": "author",
                    "firstName": "M.",
                    "lastName": "KOLOKOTRONI"
                }
            ],
            "abstractNote": "Thermal mass can be used in buildings to  reduce the need for and dependence on \nmechanical heating and cooling systems  whilst maintaining environmental comfort. \nActive thermal mass strategies further enhance the performance of thermal mass \nthrough integration with the Heating,  Ventilation and Air Conditioning (HVAC) \nsystems. For the design of new  buildings  to include active thermal mass strategies, \nexperience from operational projects and design guidelines are normally used by \nengineers. How e ver, dynamic thermal modeling is required in most cases to accurately determine the performance of its integration w i th the environmental systems of the building.  This paper outlines the calibration of dynamic thermal models of different active thermal mass strategies against measurements  in operational buildings in the UK. Three active thermal mass strategies are considered (a) hollow core slabs (b) earth-to-air heat exchanger and (c) floor void w i th mass.",
            "proceedingsTitle": "",
            "conferenceName": "Conference for the Engineering Doctorate in E nvironmental Technology",
            "publisher": "",
            "place": "",
            "date": "2008",
            "eventPlace": "",
            "volume": "",
            "issue": "",
            "numberOfVolumes": "",
            "pages": "",
            "series": "",
            "seriesNumber": "",
            "DOI": "",
            "ISBN": "",
            "citationKey": "",
            "url": "http://portal.surrey.ac.uk/pls/portal/docs/PAGE/ENG/RESEARCH/CES/ENGD/2008ENGDCONFERENCE/DAVID%20WARWICK%20PAPER.PDF",
            "accessDate": "",
            "ISSN": "",
            "archive": "",
            "archiveLocation": "",
            "shortTitle": "",
            "language": "",
            "libraryCatalog": "",
            "callNumber": "",
            "rights": "",
            "extra": "",
            "tags": [],
            "collections": [
                "7SA46WUI"
            ],
            "relations": {},
            "dateAdded": "2012-04-23T08:56:49Z",
            "dateModified": "2012-04-23T08:59:19Z"
        }
    },
    {
        "key": "XQPDKBTW",
        "version": 3,
        "library": {
            "type": "group",
            "id": 75632,
            "name": "TABS Thermo-Active-Building-Systems = thermoaktive Bauteilsysteme",
            "links": {
                "alternate": {
                    "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme",
                    "type": "text/html"
                }
            }
        },
        "links": {
            "self": {
                "href": "https://api.zotero.org/groups/75632/items/XQPDKBTW",
                "type": "application/json"
            },
            "alternate": {
                "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme/items/XQPDKBTW",
                "type": "text/html"
            }
        },
        "meta": {
            "createdByUser": {
                "id": 932721,
                "username": "anper47",
                "name": "Antonio Peretti",
                "links": {
                    "alternate": {
                        "href": "https://www.zotero.org/anper47",
                        "type": "text/html"
                    }
                }
            },
            "creatorSummary": "WARWICK",
            "parsedDate": "2011",
            "numChildren": 0
        },
        "data": {
            "key": "XQPDKBTW",
            "version": 3,
            "itemType": "document",
            "title": "INTEGRATING ACTIVE THERMAL MASS STORAGE IN RESPONSIVE BUILDINGS",
            "creators": [
                {
                    "creatorType": "author",
                    "firstName": "David",
                    "lastName": "WARWICK"
                }
            ],
            "abstractNote": "Thermal mass reduces the need and dependence on mechanical heating & cooling systems\nActive methods enhance performance by passing air of fluid across or through materials with high thermal mass\nUncertainty on how to integrate with other environmental systems in buildings\n– Simplified guidelines\n– Confidence in dynamic thermal modelling",
            "type": "",
            "date": "2011",
            "publisher": "",
            "place": "",
            "DOI": "",
            "citationKey": "",
            "url": "http://www.cibse.org/content/Groups/Building_Simulation_Group/Intergrating%20active%20thermal%20strategies%20in%20responsive%20buildings.pdf",
            "accessDate": "",
            "archive": "",
            "archiveLocation": "",
            "shortTitle": "",
            "language": "",
            "libraryCatalog": "",
            "callNumber": "",
            "rights": "",
            "extra": "",
            "tags": [],
            "collections": [
                "E7BGXVTJ"
            ],
            "relations": {
                "owl:sameAs": [
                    "http://zotero.org/groups/75827/items/43SVZPMB",
                    "http://zotero.org/groups/74663/items/J4TGXRTF"
                ]
            },
            "dateAdded": "2012-04-23T08:34:40Z",
            "dateModified": "2012-04-23T08:37:12Z"
        }
    },
    {
        "key": "8VXCQA45",
        "version": 2,
        "library": {
            "type": "group",
            "id": 75632,
            "name": "TABS Thermo-Active-Building-Systems = thermoaktive Bauteilsysteme",
            "links": {
                "alternate": {
                    "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme",
                    "type": "text/html"
                }
            }
        },
        "links": {
            "self": {
                "href": "https://api.zotero.org/groups/75632/items/8VXCQA45",
                "type": "application/json"
            },
            "alternate": {
                "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme/items/8VXCQA45",
                "type": "text/html"
            }
        },
        "meta": {
            "createdByUser": {
                "id": 932721,
                "username": "anper47",
                "name": "Antonio Peretti",
                "links": {
                    "alternate": {
                        "href": "https://www.zotero.org/anper47",
                        "type": "text/html"
                    }
                }
            },
            "creatorSummary": "KOLARIK and YANG",
            "numChildren": 0
        },
        "data": {
            "key": "8VXCQA45",
            "version": 2,
            "itemType": "document",
            "title": "EXPERT GUIDE IEA ECBCS Annex 44 Chapter 5: MASS ACTIVATION (TMA)",
            "creators": [
                {
                    "creatorType": "author",
                    "firstName": "Jakub",
                    "lastName": "KOLARIK"
                },
                {
                    "creatorType": "author",
                    "firstName": "Lina",
                    "lastName": "YANG"
                }
            ],
            "abstractNote": "",
            "type": "",
            "date": "",
            "publisher": "",
            "place": "",
            "DOI": "",
            "citationKey": "",
            "url": "http://www.ecbcs.org/docs/Annex_44_Expert_Guide_RBE.pdf",
            "accessDate": "",
            "archive": "",
            "archiveLocation": "",
            "shortTitle": "",
            "language": "",
            "libraryCatalog": "",
            "callNumber": "",
            "rights": "",
            "extra": "",
            "tags": [],
            "collections": [
                "IACUM5BK"
            ],
            "relations": {},
            "dateAdded": "2012-04-23T07:41:54Z",
            "dateModified": "2012-04-23T07:43:16Z"
        }
    },
    {
        "key": "Q557NA86",
        "version": 1,
        "library": {
            "type": "group",
            "id": 75632,
            "name": "TABS Thermo-Active-Building-Systems = thermoaktive Bauteilsysteme",
            "links": {
                "alternate": {
                    "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme",
                    "type": "text/html"
                }
            }
        },
        "links": {
            "self": {
                "href": "https://api.zotero.org/groups/75632/items/Q557NA86",
                "type": "application/json"
            },
            "alternate": {
                "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme/items/Q557NA86",
                "type": "text/html"
            }
        },
        "meta": {
            "createdByUser": {
                "id": 932721,
                "username": "anper47",
                "name": "Antonio Peretti",
                "links": {
                    "alternate": {
                        "href": "https://www.zotero.org/anper47",
                        "type": "text/html"
                    }
                }
            },
            "creatorSummary": "PANKRATZ",
            "numChildren": 0
        },
        "data": {
            "key": "Q557NA86",
            "version": 1,
            "itemType": "book",
            "title": "ENVIRONMENTAL ENGINEERING DICTIONARY and DIRECTORY",
            "creators": [
                {
                    "creatorType": "author",
                    "firstName": "Thomas M.",
                    "lastName": "PANKRATZ"
                }
            ],
            "abstractNote": "This book has been written to help professionals, students, and lay people identify\nthe increasing number of terms in the fields of environmental engineering and\nscience.\nMore than 8000 terms, acronyms, and abbreviations applying to wastewater,\npotable water, industrial water treatment, seawater desalination, air pollution, incin-\neration, and hazardous waste remediation have been defined.\nThe most unique feature of this book is the inclusion of more than 3000 trade-\nmarks and brand names. Many of these commercial terms for proprietary products\nor processes are so common or descriptive that they have fallen into general use.\nThis confusion is compounded by the fact that many terms contain similar prefixes\n(e.g., bio-, enviro-, hydra-, hydro-, etc.) and it is often difficult to tell them apart.",
            "series": "",
            "seriesNumber": "",
            "volume": "",
            "numberOfVolumes": "",
            "edition": "",
            "date": "",
            "publisher": "",
            "place": "",
            "originalDate": "",
            "originalPublisher": "",
            "originalPlace": "",
            "format": "",
            "numPages": "",
            "ISBN": "",
            "DOI": "",
            "citationKey": "",
            "url": "http://www.istanbul.edu.tr/eng2/jfm/ozcep/jeofizik/sozluk/Environmental.pdf",
            "accessDate": "",
            "ISSN": "",
            "archive": "",
            "archiveLocation": "",
            "shortTitle": "",
            "language": "",
            "libraryCatalog": "",
            "callNumber": "",
            "rights": "",
            "extra": "",
            "tags": [],
            "collections": [
                "DN2HH4UP"
            ],
            "relations": {},
            "dateAdded": "2012-04-23T06:57:09Z",
            "dateModified": "2012-04-23T06:57:09Z"
        }
    },
    {
        "key": "G3BSZFBQ",
        "version": 1,
        "library": {
            "type": "group",
            "id": 75632,
            "name": "TABS Thermo-Active-Building-Systems = thermoaktive Bauteilsysteme",
            "links": {
                "alternate": {
                    "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme",
                    "type": "text/html"
                }
            }
        },
        "links": {
            "self": {
                "href": "https://api.zotero.org/groups/75632/items/G3BSZFBQ",
                "type": "application/json"
            },
            "alternate": {
                "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme/items/G3BSZFBQ",
                "type": "text/html"
            }
        },
        "meta": {
            "createdByUser": {
                "id": 932721,
                "username": "anper47",
                "name": "Antonio Peretti",
                "links": {
                    "alternate": {
                        "href": "https://www.zotero.org/anper47",
                        "type": "text/html"
                    }
                }
            },
            "creatorSummary": "YANG et al.",
            "numChildren": 0
        },
        "data": {
            "key": "G3BSZFBQ",
            "version": 1,
            "itemType": "webpage",
            "title": "HEAT TRANSFER COEFFICIENT IN FLOW CONVECYION OF PIPE_COOLING SYSTEM in MASSIVE CONCRETE",
            "creators": [
                {
                    "creatorType": "author",
                    "firstName": "Joo-Kyoung YANG",
                    "lastName": "YANG"
                },
                {
                    "creatorType": "author",
                    "firstName": "Yun",
                    "lastName": "LEE"
                },
                {
                    "creatorType": "author",
                    "firstName": "Jin-Keun",
                    "lastName": "KIM"
                }
            ],
            "abstractNote": "Abstract:  Pipe-cooling has been widely used for reducing hydration heat and controlling cracking in massive concrete structures. Therefore, the heat transfer coefficients in flow convections, which represent the thermal transfer between the inner stream of the pipe and the concrete, must be estimated accurately. In this paper, a device measuring the heat transfer coefficient is developed based on the concept of internal forced convection. The main influencing factors on the heat transfer coefficient in the flow convection are the flow velocity, pipe diameter and thickness, and the pipe material. Using experimental results obtained from the developed device, a general prediction model for heat transfer coefficients is suggested. The proposed prediction model was found to estimate the heat transfer coefficient correctly with respect to the properties of the flow and pipe in comparisons of measured data and the numerical results of a heat transfer analysis conducted on an actual massive concrete structure.",
            "websiteTitle": "",
            "websiteType": "",
            "date": "",
            "publisher": "",
            "place": "",
            "DOI": "",
            "citationKey": "",
            "url": "http://www.jstage.jst.go.jp/article/jact/9/1/9_103/_article",
            "accessDate": "2012-04-11T07:04:48Z",
            "shortTitle": "",
            "language": "",
            "rights": "",
            "extra": "",
            "tags": [],
            "collections": [
                "D362F3RT"
            ],
            "relations": {},
            "dateAdded": "2012-04-21T15:13:44Z",
            "dateModified": "2012-04-21T15:13:44Z"
        }
    },
    {
        "key": "4TD6BABX",
        "version": 3,
        "library": {
            "type": "group",
            "id": 75632,
            "name": "TABS Thermo-Active-Building-Systems = thermoaktive Bauteilsysteme",
            "links": {
                "alternate": {
                    "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme",
                    "type": "text/html"
                }
            }
        },
        "links": {
            "self": {
                "href": "https://api.zotero.org/groups/75632/items/4TD6BABX",
                "type": "application/json"
            },
            "alternate": {
                "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme/items/4TD6BABX",
                "type": "text/html"
            }
        },
        "meta": {
            "createdByUser": {
                "id": 932721,
                "username": "anper47",
                "name": "Antonio Peretti",
                "links": {
                    "alternate": {
                        "href": "https://www.zotero.org/anper47",
                        "type": "text/html"
                    }
                }
            },
            "creatorSummary": "Oleson and Liedelt",
            "numChildren": 0
        },
        "data": {
            "key": "4TD6BABX",
            "version": 3,
            "itemType": "book",
            "title": "Cooling and Heating of Buildings by Activating their Thermal Mass with Embedded Hydronic Pipe Systems",
            "creators": [
                {
                    "creatorType": "author",
                    "firstName": "B. W.",
                    "lastName": "Oleson"
                },
                {
                    "creatorType": "author",
                    "firstName": "D. F.",
                    "lastName": "Liedelt"
                }
            ],
            "abstractNote": "Due to intensive  use of energy and high costs in several European\ncountries it is often debated if air-conditioning of buildings is recommendable\nor should be prohibited by law.  Of course, air-conditioning will give better\ncontrol of the indoor temperature and then improve comfort and productivity. But there also exist many examples of discomfort in air-conditioned buildings due to draught, noise and sick building syndrome.  By air-conditioning, heating, cooling and ventilation are achieved alone by  air, where the cooling and heating requirements determine the amount of required air circulation. Alternatively, the heating and sensible component of cooling may be done by hydronic radiant heating and cooling systems, where pipes are embedded in concrete slabs between each storey. The system may be combined with a ventilation system, where the amount of outside air is based on the requirements for acceptable are quality. This paper discusses the possibilities and limitations of such heating and cooling systems, and examples of buildings having this type of systems are presented.",
            "series": "",
            "seriesNumber": "",
            "volume": "",
            "numberOfVolumes": "",
            "edition": "",
            "date": "",
            "publisher": "Retrieved from e Chartered Institution of Building Services Engineers: http://www. cibse. org/pdfs/Embedded% 20Hydronic% 20Pipe% 20Sys. pdf",
            "place": "",
            "originalDate": "",
            "originalPublisher": "",
            "originalPlace": "",
            "format": "",
            "numPages": "",
            "ISBN": "",
            "DOI": "",
            "citationKey": "",
            "url": "http://www.cibse.org/pdfs/Embedded%20Hydronic%20Pipe%20Sys.pdf",
            "accessDate": "",
            "ISSN": "",
            "archive": "",
            "archiveLocation": "",
            "shortTitle": "",
            "language": "",
            "libraryCatalog": "Google Scholar",
            "callNumber": "",
            "rights": "",
            "extra": "",
            "tags": [],
            "collections": [
                "IACUM5BK"
            ],
            "relations": {},
            "dateAdded": "2012-04-17T17:00:21Z",
            "dateModified": "2012-04-20T16:01:38Z"
        }
    },
    {
        "key": "K2MVG76E",
        "version": 1,
        "library": {
            "type": "group",
            "id": 75632,
            "name": "TABS Thermo-Active-Building-Systems = thermoaktive Bauteilsysteme",
            "links": {
                "alternate": {
                    "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme",
                    "type": "text/html"
                }
            }
        },
        "links": {
            "self": {
                "href": "https://api.zotero.org/groups/75632/items/K2MVG76E",
                "type": "application/json"
            },
            "alternate": {
                "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme/items/K2MVG76E",
                "type": "text/html"
            },
            "up": {
                "href": "https://api.zotero.org/groups/75632/items/CP8MU63X",
                "type": "application/json"
            }
        },
        "meta": {
            "createdByUser": {
                "id": 932721,
                "username": "anper47",
                "name": "Antonio Peretti",
                "links": {
                    "alternate": {
                        "href": "https://www.zotero.org/anper47",
                        "type": "text/html"
                    }
                }
            }
        },
        "data": {
            "key": "K2MVG76E",
            "version": 1,
            "parentItem": "CP8MU63X",
            "itemType": "attachment",
            "linkMode": "linked_url",
            "title": "Amazon.com Link",
            "accessDate": "2012-04-19T09:39:51Z",
            "url": "http://www.amazon.com/dp/047084731X",
            "note": "",
            "contentType": "text/html",
            "charset": "",
            "tags": [],
            "relations": {},
            "dateAdded": "2012-04-19T09:39:51Z",
            "dateModified": "2012-04-19T09:39:51Z"
        }
    },
    {
        "key": "CP8MU63X",
        "version": 1,
        "library": {
            "type": "group",
            "id": 75632,
            "name": "TABS Thermo-Active-Building-Systems = thermoaktive Bauteilsysteme",
            "links": {
                "alternate": {
                    "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme",
                    "type": "text/html"
                }
            }
        },
        "links": {
            "self": {
                "href": "https://api.zotero.org/groups/75632/items/CP8MU63X",
                "type": "application/json"
            },
            "alternate": {
                "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme/items/CP8MU63X",
                "type": "text/html"
            }
        },
        "meta": {
            "createdByUser": {
                "id": 932721,
                "username": "anper47",
                "name": "Antonio Peretti",
                "links": {
                    "alternate": {
                        "href": "https://www.zotero.org/anper47",
                        "type": "text/html"
                    }
                }
            },
            "creatorSummary": "Davies",
            "parsedDate": "2004-05-31",
            "numChildren": 1
        },
        "data": {
            "key": "CP8MU63X",
            "version": 1,
            "itemType": "book",
            "title": "Building Heat Transfer",
            "creators": [
                {
                    "creatorType": "author",
                    "firstName": "Morris Grenfell",
                    "lastName": "Davies"
                }
            ],
            "abstractNote": "",
            "series": "",
            "seriesNumber": "",
            "volume": "",
            "numberOfVolumes": "",
            "edition": "1",
            "date": "2004-05-31",
            "publisher": "Wiley",
            "place": "",
            "originalDate": "",
            "originalPublisher": "",
            "originalPlace": "",
            "format": "",
            "numPages": "524",
            "ISBN": "047084731X",
            "DOI": "",
            "citationKey": "",
            "url": "",
            "accessDate": "",
            "ISSN": "",
            "archive": "",
            "archiveLocation": "",
            "shortTitle": "",
            "language": "",
            "libraryCatalog": "Amazon.com",
            "callNumber": "",
            "rights": "",
            "extra": "",
            "tags": [],
            "collections": [
                "D362F3RT"
            ],
            "relations": {},
            "dateAdded": "2012-04-19T09:39:51Z",
            "dateModified": "2012-04-19T09:39:51Z"
        }
    },
    {
        "key": "UW4TGD9Q",
        "version": 3,
        "library": {
            "type": "group",
            "id": 75632,
            "name": "TABS Thermo-Active-Building-Systems = thermoaktive Bauteilsysteme",
            "links": {
                "alternate": {
                    "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme",
                    "type": "text/html"
                }
            }
        },
        "links": {
            "self": {
                "href": "https://api.zotero.org/groups/75632/items/UW4TGD9Q",
                "type": "application/json"
            },
            "alternate": {
                "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme/items/UW4TGD9Q",
                "type": "text/html"
            }
        },
        "meta": {
            "createdByUser": {
                "id": 932721,
                "username": "anper47",
                "name": "Antonio Peretti",
                "links": {
                    "alternate": {
                        "href": "https://www.zotero.org/anper47",
                        "type": "text/html"
                    }
                }
            },
            "creatorSummary": "VOIT et al.",
            "numChildren": 0
        },
        "data": {
            "key": "UW4TGD9Q",
            "version": 3,
            "itemType": "webpage",
            "title": "Campina Verwaltungsgebäude, Heilbronn",
            "creators": [
                {
                    "creatorType": "author",
                    "firstName": "Peter",
                    "lastName": "VOIT"
                },
                {
                    "creatorType": "author",
                    "firstName": "Thomas",
                    "lastName": "FIEDLER"
                },
                {
                    "creatorType": "author",
                    "firstName": "Stefan",
                    "lastName": "HOLST"
                }
            ],
            "abstractNote": "Bei der Planung des neuen Firmensitzes der Molkerei Campina AG in Heilbronn am Neckar schlugen die Planer als Alternative zu den herkömmlichen Klimatisierungskonzepten ein thermoaktives Bauteilsystem (tabs) vor. Für die Bauherrschaft und die Architekten war «tabs» ein Fremdwort (das ist so nicht ganz richtig, Anm. der Red.). Sie wollten daher Gewissheit, dass das System funktioniert. Mittels einer dynamischen Gebäudesimulation mit dem Programmpaket TRNSYS [1] wurden das Energiekonzept daher geprüft und die entscheidenden Parameter des Lüftungskonzepts und der Bauteilkonditionierung im Hinblick auf Komfort, Funktionssicherheit und Kostenaspekte hin optimiert. Anhand der Resultate wurde gezeigt, dass das vorgeschlagene Klimakonzept, bestehend aus Bauteilkühlung, Nachtluftspülung, Schachtentlüftung und Fensterlüftung, ein im Vergleich zu anderen Systemen kostengünstiges, energie- und kubatursparendes Konzept ist, das auch bei sommerlichen Extrembedingungen komfortable Raumbedingungen herzustellen vermag. Heute, knapp zwei Jahre nach dem Bezug des Gebäudes, bestätigen Messungen die Resultate der damaligen Berechnungen.",
            "websiteTitle": "",
            "websiteType": "",
            "date": "",
            "publisher": "",
            "place": "",
            "DOI": "",
            "citationKey": "",
            "url": "http://www.knopp-architekten.de/neub/cmpv-presse/cmpv-presse.html",
            "accessDate": "2012-04-18T20:44:58Z",
            "shortTitle": "",
            "language": "",
            "rights": "",
            "extra": "",
            "tags": [],
            "collections": [
                "7SA46WUI"
            ],
            "relations": {},
            "dateAdded": "2012-04-18T20:44:58Z",
            "dateModified": "2012-04-18T20:46:44Z"
        }
    },
    {
        "key": "RKDKURM6",
        "version": 1,
        "library": {
            "type": "group",
            "id": 75632,
            "name": "TABS Thermo-Active-Building-Systems = thermoaktive Bauteilsysteme",
            "links": {
                "alternate": {
                    "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme",
                    "type": "text/html"
                }
            }
        },
        "links": {
            "self": {
                "href": "https://api.zotero.org/groups/75632/items/RKDKURM6",
                "type": "application/json"
            },
            "alternate": {
                "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme/items/RKDKURM6",
                "type": "text/html"
            }
        },
        "meta": {
            "createdByUser": {
                "id": 932721,
                "username": "anper47",
                "name": "Antonio Peretti",
                "links": {
                    "alternate": {
                        "href": "https://www.zotero.org/anper47",
                        "type": "text/html"
                    }
                }
            },
            "creatorSummary": "BRUNNER",
            "parsedDate": "1999",
            "numChildren": 0
        },
        "data": {
            "key": "RKDKURM6",
            "version": 1,
            "itemType": "thesis",
            "title": "Untersuchung geeigneter Regelungsstrategien für thermisch aktive Decken in Bürogebäuden mit Hilfe der Computersimulation und dem Ziel der Nutzung von Umweltenergie",
            "creators": [
                {
                    "creatorType": "author",
                    "firstName": "Tobias",
                    "lastName": "BRUNNER"
                }
            ],
            "abstractNote": "Thermisch aktive Decken können als Sonderfall der bekannten Flächenheiz- und -kühlsysteme wie Fußbodenheizung und Kühldecke verstanden werden. Hauptkomponente sind wie dort in Decken, Böden oder Wänden eingebaute, wasserführende Rohrregister. Der Unterschied besteht jedoch darin, daß die Rohre nicht dicht unter der Oberfläche verlegt werden, sondern zwischen oberer und unterer Bewehrung in der Betonschicht. Dadurch wird die speichernde Masse des Gebäudes relativ gleichmäßig temperiert. Durch diese Speicherwirkung ist es möglich, tages- und jahreszeitlich auftretende Lastspitzen sowohl im Kühl- als auch zunehmend im Heizbetrieb zu dämpfen und einen Teil der anfallenden Lasten in der Gebäudemasse zu speichern. Die Einsatzmöglichkeit für den Heizbetrieb hängt aufgrund der niedrigen möglichen Wärmeabgabe der Bauteile eng mit der Wärmedämmung des Gebäudes zusammen, hier sind jedoch in Zukunft weitere Verbesserungen zu erwarten.",
            "thesisType": "",
            "university": "",
            "place": "",
            "date": "1999",
            "series": "",
            "seriesNumber": "",
            "numPages": "",
            "DOI": "",
            "ISBN": "",
            "citationKey": "",
            "url": "http://www.diplom.de/Untersuchung-geeigneter-Regelungsstrategien-thermisch-aktive-Decken-Buerogebaeuden-Hilfe-Computersimulation-Ziel-Umweltenergie/1768.html",
            "accessDate": "2012-04-18T20:42:09Z",
            "ISSN": "",
            "archive": "",
            "archiveLocation": "",
            "shortTitle": "",
            "language": "",
            "libraryCatalog": "",
            "callNumber": "",
            "rights": "",
            "extra": "",
            "tags": [],
            "collections": [
                "8M4T94Q5"
            ],
            "relations": {},
            "dateAdded": "2012-04-18T20:42:09Z",
            "dateModified": "2012-04-18T20:43:50Z"
        }
    },
    {
        "key": "PXE5XEUR",
        "version": 4,
        "library": {
            "type": "group",
            "id": 75632,
            "name": "TABS Thermo-Active-Building-Systems = thermoaktive Bauteilsysteme",
            "links": {
                "alternate": {
                    "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme",
                    "type": "text/html"
                }
            }
        },
        "links": {
            "self": {
                "href": "https://api.zotero.org/groups/75632/items/PXE5XEUR",
                "type": "application/json"
            },
            "alternate": {
                "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme/items/PXE5XEUR",
                "type": "text/html"
            }
        },
        "meta": {
            "createdByUser": {
                "id": 932721,
                "username": "anper47",
                "name": "Antonio Peretti",
                "links": {
                    "alternate": {
                        "href": "https://www.zotero.org/anper47",
                        "type": "text/html"
                    }
                }
            },
            "creatorSummary": "GLÜCK",
            "parsedDate": "1999",
            "numChildren": 0
        },
        "data": {
            "key": "PXE5XEUR",
            "version": 4,
            "itemType": "document",
            "title": "Bauteilheizung  und  Bauteilkühlung  mit einem  Maximum  an  Umweltenergie  unterbesonderer Berücksichtigung  des Einsatzes von  Kapillarrohrmatten",
            "creators": [
                {
                    "creatorType": "author",
                    "firstName": "Bernd",
                    "lastName": "GLÜCK"
                }
            ],
            "abstractNote": "Die thermi sche Bauteilaktivierung umfasst generell stationär und instationär arbeitende Heiz- und Kühlsystem e, die direkt in den Baukörper (W ände, Decken, Boden, Säulen usw.) integriert sind.  Die neuzeitliche thermi sche Bauteilaktivierung se tzt wasserdurchflossene Rohrsystem e in Speicherbauteilen – vorzugsweise in Massivdecken - ein. Die Be- und die Entladung erfolgen zeitversetzt, wom it ein instationärer Betrieb gegeben  ist. Der Begriff \"Aktivierung\" bezieht sich auf das gezielte Speichern von Wä rme im  Bauteil,  die Entladung erfolgt rein passiv ohne Eingriffsmöglichkeit durch den Nutzer. Es soll vorzugsweise Um weltenergie zum Einsatz kommen.",
            "type": "",
            "date": "1999",
            "publisher": "",
            "place": "",
            "DOI": "",
            "citationKey": "",
            "url": "http://www.bosy-online.de/Betonkernaktivierung/RomSt_P9_Zusammenfasg.pdf",
            "accessDate": "",
            "archive": "",
            "archiveLocation": "",
            "shortTitle": "",
            "language": "",
            "libraryCatalog": "",
            "callNumber": "",
            "rights": "",
            "extra": "",
            "tags": [],
            "collections": [
                "6I3QN54G"
            ],
            "relations": {},
            "dateAdded": "2012-04-18T20:37:27Z",
            "dateModified": "2012-04-18T20:41:13Z"
        }
    },
    {
        "key": "4CNM5NST",
        "version": 4,
        "library": {
            "type": "group",
            "id": 75632,
            "name": "TABS Thermo-Active-Building-Systems = thermoaktive Bauteilsysteme",
            "links": {
                "alternate": {
                    "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme",
                    "type": "text/html"
                }
            }
        },
        "links": {
            "self": {
                "href": "https://api.zotero.org/groups/75632/items/4CNM5NST",
                "type": "application/json"
            },
            "alternate": {
                "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme/items/4CNM5NST",
                "type": "text/html"
            }
        },
        "meta": {
            "createdByUser": {
                "id": 932721,
                "username": "anper47",
                "name": "Antonio Peretti",
                "links": {
                    "alternate": {
                        "href": "https://www.zotero.org/anper47",
                        "type": "text/html"
                    }
                }
            },
            "creatorSummary": "TIAN and LOVE",
            "parsedDate": "2005",
            "numChildren": 0
        },
        "data": {
            "key": "4CNM5NST",
            "version": 4,
            "itemType": "conferencePaper",
            "title": "AN INTEGRATED STUDY OF RADIANT  SLAB COOLING SYSTEMS THROUGH EXPERIMENT AND BUILDING SIMULATION",
            "creators": [
                {
                    "creatorType": "author",
                    "firstName": "Zhen",
                    "lastName": "TIAN"
                },
                {
                    "creatorType": "author",
                    "firstName": "James A.",
                    "lastName": "LOVE"
                }
            ],
            "abstractNote": "Radiant cooling systems for thermal comfort in commercial buildings are new to North America.  The University of Calgary’s ICT Building has a hybrid radiant slab-mixed ai r system that offers an opportunity to evaluate operating performance. Through integrated field measurements and building simulation with  EnergyPlus , it was found that the building energy performance could be improved by reducing conflicts between systems, especially simultaneous heating and cooling. Control strategies to coordinate air and radiant system operation are crucial to improve the overall building energy performance. Use of “low quality” cooling sources with radiant slab cooling was also considered.",
            "proceedingsTitle": "",
            "conferenceName": "",
            "publisher": "",
            "place": "",
            "date": "2005",
            "eventPlace": "",
            "volume": "",
            "issue": "",
            "numberOfVolumes": "",
            "pages": "",
            "series": "",
            "seriesNumber": "",
            "DOI": "",
            "ISBN": "",
            "citationKey": "",
            "url": "http://www.ibpsa.org/proceedings/BS2005/BS05_1229_1236.pdf",
            "accessDate": "",
            "ISSN": "",
            "archive": "",
            "archiveLocation": "",
            "shortTitle": "",
            "language": "",
            "libraryCatalog": "",
            "callNumber": "",
            "rights": "",
            "extra": "",
            "tags": [],
            "collections": [
                "6I3QN54G"
            ],
            "relations": {},
            "dateAdded": "2012-04-18T20:26:57Z",
            "dateModified": "2012-04-18T20:29:47Z"
        }
    },
    {
        "key": "ACHE8CIE",
        "version": 4,
        "library": {
            "type": "group",
            "id": 75632,
            "name": "TABS Thermo-Active-Building-Systems = thermoaktive Bauteilsysteme",
            "links": {
                "alternate": {
                    "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme",
                    "type": "text/html"
                }
            }
        },
        "links": {
            "self": {
                "href": "https://api.zotero.org/groups/75632/items/ACHE8CIE",
                "type": "application/json"
            },
            "alternate": {
                "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme/items/ACHE8CIE",
                "type": "text/html"
            }
        },
        "meta": {
            "createdByUser": {
                "id": 932721,
                "username": "anper47",
                "name": "Antonio Peretti",
                "links": {
                    "alternate": {
                        "href": "https://www.zotero.org/anper47",
                        "type": "text/html"
                    }
                }
            },
            "creatorSummary": "DE CARLI and OLESEN",
            "numChildren": 0
        },
        "data": {
            "key": "ACHE8CIE",
            "version": 4,
            "itemType": "conferencePaper",
            "title": "Field Measurements of Thermal Comfort Conditions in Buildings with Radiant Surface Cooling Systems",
            "creators": [
                {
                    "creatorType": "author",
                    "firstName": "Michele",
                    "lastName": "DE CARLI"
                },
                {
                    "creatorType": "author",
                    "firstName": "Bjarne W.",
                    "lastName": "OLESEN"
                }
            ],
            "abstractNote": "The performance of radiant heating systems (floor heating, ceiling panels) is relatively well documented. Water based systems, where pipes are embedded in the building structure, are now being increasingly used for cooling purposes. Several theoretical studies based on the use of computer simulations have been published, but very little is reported on the actual performance in existing buildings. There are still uncertainties on how such systems operate\nand on how well the space temperatures under varying external and internal load is kept within the comfort range.\nTo study this aspect, field measurements of thermal comfort conditions were made in several buildings with radiant surface cooling systems. The systems comprise floor cooling, wall cooling and cooling with pipes embedded in the concrete slabs between each floor in a multi storey building. Long term measurements of operative, air, surface, system and external temperatures have been carried out. The analysis of the data shows that, for the major part of the time of occupancy, the operative temperature is inside the comfort range. The analysis has been lead for different classes of comfort according to existing standards. The data show an increase in space temperature during the day, which is counterbalanced by a corresponding decrease during the night. This study shows that hydronic radiant cooling systems in many buildings are an interesting alternative to full air conditioning systems, for obtaining acceptable indoor thermal environments during summer.",
            "proceedingsTitle": "",
            "conferenceName": "",
            "publisher": "",
            "place": "",
            "date": "",
            "eventPlace": "",
            "volume": "",
            "issue": "",
            "numberOfVolumes": "",
            "pages": "",
            "series": "",
            "seriesNumber": "",
            "DOI": "",
            "ISBN": "",
            "citationKey": "",
            "url": "http://www.google.com/url?q=http://citeseerx.ist.psu.edu/viewdoc/download%3Fdoi%3D10.1.1.202.1741%26rep%3Drep1%26type%3Dpdf&sa=U&ei=dSGPT6eyEIGQ0AWHpOj6AQ&ved=0CAcQFjAB&client=internal-uds-cse&usg=AFQjCNElbzOZn_Lq9tWoq-bHZupNBw8vOQ",
            "accessDate": "",
            "ISSN": "",
            "archive": "",
            "archiveLocation": "",
            "shortTitle": "",
            "language": "",
            "libraryCatalog": "",
            "callNumber": "",
            "rights": "",
            "extra": "",
            "tags": [],
            "collections": [
                "6I3QN54G"
            ],
            "relations": {
                "owl:sameAs": "http://zotero.org/groups/75827/items/2M4CHXQT"
            },
            "dateAdded": "2012-04-18T20:19:47Z",
            "dateModified": "2012-04-18T20:23:20Z"
        }
    },
    {
        "key": "BA7PSEAG",
        "version": 1,
        "library": {
            "type": "group",
            "id": 75632,
            "name": "TABS Thermo-Active-Building-Systems = thermoaktive Bauteilsysteme",
            "links": {
                "alternate": {
                    "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme",
                    "type": "text/html"
                }
            }
        },
        "links": {
            "self": {
                "href": "https://api.zotero.org/groups/75632/items/BA7PSEAG",
                "type": "application/json"
            },
            "alternate": {
                "href": "https://www.zotero.org/groups/tabs_thermo-active-building-systems__thermoaktive_bauteilsysteme/items/BA7PSEAG",
                "type": "text/html"
            }
        },
        "meta": {
            "createdByUser": {
                "id": 932721,
                "username": "anper47",
                "name": "Antonio Peretti",
                "links": {
                    "alternate": {
                        "href": "https://www.zotero.org/anper47",
                        "type": "text/html"
                    }
                }
            },
            "creatorSummary": "GLÜCK",
            "numChildren": 0
        },
        "data": {
            "key": "BA7PSEAG",
            "version": 1,
            "itemType": "webpage",
            "title": "Prof. Dr. Bernd Glück Heizungs- und Klimatechnik",
            "creators": [
                {
                    "creatorType": "author",
                    "firstName": "Bernd",
                    "lastName": "GLÜCK"
                }
            ],
            "abstractNote": "",
            "websiteTitle": "",
            "websiteType": "",
            "date": "",
            "publisher": "",
            "place": "",
            "DOI": "",
            "citationKey": "",
            "url": "http://berndglueck.de/",
            "accessDate": "2012-04-04T13:31:54Z",
            "shortTitle": "",
            "language": "",
            "rights": "",
            "extra": "",
            "tags": [],
            "collections": [
                "D362F3RT"
            ],
            "relations": {
                "owl:sameAs": "http://zotero.org/groups/75827/items/AAPZRRVZ"
            },
            "dateAdded": "2012-04-16T18:12:00Z",
            "dateModified": "2012-04-18T18:51:13Z"
        }
    }
]